Advanced Static Var Generator(ASVG-5-0.22-2L-R)

Get advanced static var generator (ASVG-5-0.22-2L-R) from our factory. High-quality, reliable and efficient solution for power factor correction. Order now!

Request a Quote
  • Advanced Static Var Generator(ASVG-5-0.22-2L-R)
  • Advanced Static Var Generator(ASVG-5-0.22-2L-R)
  • Advanced Static Var Generator(ASVG-5-0.22-2L-R)
  • Advanced Static Var Generator(ASVG-5-0.22-2L-R)

PRODUCTS DETAILS

Working Principle

The principle of the SVG is very similar to that of Active harmonic Filter, When the load is generating inductive or capacitive current, it makes load current lagging or leading the voltage. SVG detects the phase angle difference and generates leading or lagging current into the grid, making the phase angle of current almost the same as that of voltage on the transformer side, which means fundamental power factor is unit. YIY-SVG is also capable of correcting load imbalance.

Technical Specifications

Technical Specification 220V    Series 400V    Series 500V    Series 690V    Series
Rated Compensation Capacity 5Kvar 10KVar15KVar/35KVar/50KVar75KVar/100KVar 90Kvar 100Kvar/120Kvar
Nominal Voltage AC220V(-20%~+15%) AC400V(-40%~+15%) AC500V(-20%~+15%) AC690V(-20%~+15%)
Rated Frequency 50/60Hz±5%
Grid Structure Single phase 3 phase 3 wire/3 phase 4 wire
Number of paralle No limitation.A single centralized monitoring module can be equipped with up to 8 power modules.
Machine Efficiency >97%
Switching Efficiency 32kHz 16kHz 12.8kHz 12.8kHz
Function Reactive /Reactive and Harmonic Reactive /Reactive and harmonic /Reactive and imbalance (optional)
Reactive Power Compensation Rate >99%
Harmonic  Compensation Capacity 70%SOC
Harmonic Compensation Times 2-13 times
Response Time <10ms
Noise <50dB <60dB <65dB
Communication Method Two-channel RS485 communication interface (support GPRS/WIFI wireless communication)
Monitoring Method 4.3 inch LCD small-sized screen /7 inch LCD centralized monitoring screen
Protection Over load protection,hardware/software over current protection,over grid power protection /under grid power protection,grid power voltage imbalance protection,power failure protection,over temperature protection,frequency anomaly protection,short circuit protection,etc
Altitude ≤2000Meters ≤2000Meters ≤2000Meters ≤2000Meters
Ambient Temperature -20~+50°C -20~+50℃ -20~+50°C -20~+50°C
Relative Humidity <90%,The average monthly minimum temperature is 25°C without condensation on the surface
Pollution Level Below level III
nstallation RackWall-mounted
Wiring Patter Back entry (Rack type)Top entry (Wall mounted type)
Protection Grade IP20
Color White
   

Product naming

Product Appearance

Hot Products

Advanced Static Var Generator(ASVG-5-0.22-2L-R)

Advanced Static Var Generator(ASVG-5-0.22-2L-R)

Active Harmonic Filters(AHF-50-0.4-4L-W)

Active Harmonic Filters(AHF-50-0.4-4L-W)

Advanced Static Var Generator(ASVG-100-0.4-4L-R)

Advanced Static Var Generator(ASVG-100-0.4-4L-R)

Static Var Generator(SVG-10-0.4-4L-W)

Static Var Generator(SVG-10-0.4-4L-W)

Static Var Generator Cabinet (50Kvar-300Kvar)

Static Var Generator Cabinet (50Kvar-300Kvar)

Static Var Generator(SVG-35-0.4-4L-R)

Static Var Generator(SVG-35-0.4-4L-R)

Static Var Generator(SVG-15-0.4-4L-R)

Static Var Generator(SVG-15-0.4-4L-R)

Active Harmonic Filters(AHF-15-0.4-4L-R)

Active Harmonic Filters(AHF-15-0.4-4L-R)

Active Voltage Conditioner (AVC)

Active Voltage Conditioner (AVC)

Advanced Static Var Generator(ASVG-75-0.4-4L-W)

Advanced Static Var Generator(ASVG-75-0.4-4L-W)

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours